SSN Makina Machinery Company
AI Data Center Project — Proposal Presentation
AI Data Center Project

Modular Power Unit — Turnkey Power and Infrastructure Solution

SSN Makina delivers your data center’s entire module — from power distribution to cooling, fire safety, monitoring, and physical security — as a single, factory-integrated, fully tested product certified to U.S. standards. The entire process is managed under one responsible party, with a single point of contact.

SSN Makina A.Ş. — Engineering, manufacturing, and field integration under one roof

What sets us apart

The same equipment can be assembled in many different ways — what sets us apart is delivering it from a single source, under one responsibility, fully tested from start to finish.

Single responsible party, turnkey

Design, manufacturing, testing, and field integration are all managed under one roof — no need to coordinate multiple suppliers.

The entire module is designed with UL 2755 in mind

The goal is evaluation of the whole module as a single product, not piecemeal component certification.

N+1 redundant architecture

Redundancy in the cooling and power systems ensures uninterrupted operation.

100% factory tested

Full functional testing is completed before shipment, minimizing the time spent on site.

Compliance with multiple U.S. standards in a single package

UL, NFPA, ASCE, and IEEE requirements are met within a single delivery, not separately.

Predictable delivery schedule

Factory prefabrication shortens on-site time and clarifies the project schedule.

Our scope of delivery

The module — with all its subsystems, from main electrical distribution to physical security — is designed, manufactured, and tested fully prefabricated at the factory, then commissioned on site.

Main distribution panel

Main switchgear with transformer and generator inputs, UPS, and critical load distribution

UPS and energy storage

Double-conversion UPS and battery bank, synchronization and bypass system

Cooling system

N+1 redundant hydronic cooling, full heat load capacity

Fire safety

Detection and suppression system, integrated with the building fire system

Monitoring and automation

BMS/DCIM integration, real-time status and alarm monitoring

Physical security

Access control, door sensors, and video surveillance system

Structural integration

Fire-resistant, transportable, factory-prepared enclosed structure

Commissioning and testing

Factory acceptance testing, certification, and on-site commissioning support

Standards we work with

The module is delivered with all certification and code compliance required for use in the United States.

UL 2755
Certification of prefabricated modular data center units as a whole
UL 508A / UL 891
Manufacturing and labeling standard for control panels and switchboards
NFPA 70 (NEC)
U.S. National Electrical Code — wiring and equipment compliance
NFPA 72 / 76
Fire alarm and detection systems standard
NFPA 2001
Clean agent fire extinguishing systems standard
ASCE 7
Structural load calculations (wind, seismic, transport)
ASME BTH-1
Design standard for below-the-hook lifting devices and lifting points
IEEE standards
Short-circuit current and protection coordination calculations

3D layout of the module

The module is shipped to site as a single piece and is lifted from above by crane using its 4 corner lifting points, compliant with ISO 1496-1 / ISO 1161; forklift pockets compliant with ISO 3874 are built into the chassis for transport and on-site handling. There is no separate external connection for the load bank — this connection is located on the MSB's own internal busbar, inside the container.

Module exterior layout image
Representative engineering render — approximate exterior dimensions are based on a standard 40 ft high-cube container; exact dimensions and equipment models will be determined in the engineering drawings.

Interior layout — cutaway view

Engineering cutaway with the long side wall removed: shows the layout of all subsystems — from cooling units and battery racks to power conversion systems (PCS) and the main distribution panel — along with internal busbar routing and airflow direction. This image is representative; equipment dimensions and power values are schematic and do not represent actual figures.

Module interior cutaway image
Representative engineering render — equipment types and architectural layout are shown; brand, model, dimensions, and power values are not representative

Connection interfaces

All input/output points are prepared and tested at the factory; only standard connection work is performed on site — no hot work or wet work is required. The electrical/mechanical rating and connection method for each interface is specified below.

Electrical interfaces

  • Transformer → MSB480V AC, 4000A — connects via busbar/cable lug to a factory-prepared terminal
  • Generator → MSB480V AC, 4000A — connects via busbar/cable lug to a factory-prepared terminal
  • Load bank connection point480V AC, 4000A — not a separate external input; supplied from inside the container via the MSB's own internal busbar
  • Computer room (IT) PDU outputs4 lines, 1250A — IP-rated cable entry plate, industrial connector interface
  • Mechanical system outputs2 lines, 1250A — IP-rated cable entry plate, industrial connector interface

Mechanical interfaces

  • Main cooling line2 independent connections — flanged pipe connection, on the exterior wall
  • Fire suppression connectionFlanged / grooved connection on the exterior wall; internal distribution via a ceiling-mounted manifold and nozzles
  • Ventilation / emergency exhaustSized per calculation, louvered outlet on the exterior wall
  • Drainage / condensateDischarged outside the module at floor level
  • Forklift / lifting pointsISO 3874 (forklift pockets), ISO 1496-1 / ISO 1161 (lifting points)

Automation and monitoring

  • Local network / Modbus TCPBMS and DCIM integration — via network interface
  • Fire alarm terminalDry contact / addressable connection to the central fire panel
  • Access control / CCTVIntegration via terminal box / network interface
  • Dry contact alarmsFire, leak, UPS status, door open/closed signal
Siemens
One of the brands we work with directly for main distribution, protection, and automation equipment
Schneider Electric
One of the brands we work with directly for switchgear, UPS, and monitoring systems
Eaton
One of the brands we work with directly for power distribution and protection equipment

Equipment brand/model selection is made from among these three brands based on the project specification and customer preference; turnkey responsibility rests with SSN Makina in all cases.